Outputs

What you hand over

Each design produces a design report and installation drawings with a materials list as PDF, a DXF file for CAD, a site survey sheet and a commissioning record. Open real examples below, made by the app from one fictional project.

Every example is fictional. “Example: Civic Center Council Chamber” is a made-up 70 by 56 ft council chamber with a concrete floor over a steel deck, looped with a uniformity-optimized phased array of four elements. The people, company, customer and address are invented; the loop driver is a real product the app chose for this room from its catalog. Shown in US (imperial) units.

Design report

A PDF that sets out the design and the modeled result, so the client, the consultant and the crew all read the same numbers.

  • Project, area and designer, with the date and time it was generated.
  • Loop design: loop size and area, loop type, the wall boundary with the gap to each wall, listening height, effective field height and the audience margin.
  • The selected driver: brand and model, whether it suits the load, required against maximum voltage and current, channels and the loop resistance it accepts.
  • Installation and wiring: wire orientation, loop wire and turns, loop height, feeder cable and feeder length, and the phase shift between channels.
  • Where the metal-loss figures came from.
  • Electrical load for each driver channel: wire length, DC resistance, inductance, impedance, the current needed at 1.6 kHz and the drive voltage at 1, 1.6 and 5 kHz.
  • A layout preview, a 3D map of the field and a cross-section, with the modeled field variance, lowest and highest level, and evenness inside the audience area and over the whole area.
  • A wiring layout page with each element’s position, and a materials page.
Example: Civic Center Council ChamberExample
First page of the example design report for the fictional council chamber: loop design, selected driver, installation and wiring, electrical load per channel, layout preview, 3D field map and cross-section.
Open the example PDF: design report 3 pages · 315 KB · opens in a new tab

Installation drawings

Drawing sheets the crew can install from, dimensioned in feet or meters.

  • The overall system layout, and for a phased array, the Phase A and Phase B layouts on their own sheets.
  • For an array, a configuration table: each element’s channel, polarity, start, end, span and overlap.
  • Dimensions measured from a marked origin corner.
  • A title block on every sheet: company, drawing title, customer, venue, site address, room, loop section, project number, issue status, revision, designer and role, checked by, issue date, drawing number, scale, units and sheet.
  • Notes on every sheet, including that written dimensions govern and that crossing gaps are underpasses, not wire breaks.
  • A materials sheet, and a closing sheet of installation checks and commissioning steps, with a schematic for wiring a star-quad feeder.
Example: Civic Center Council ChamberExample
First sheet of the example installation drawings: the overall layout of the four-element phased array in the room, dimensioned from the origin corner, with notes and a title block for the fictional project.
Open the example PDF: installation drawings 6 sheets · 299 KB · opens in a new tab

Materials list

What to order for the job, with the specified product or part number on each line. It prints as a page of the design report and as a sheet of the installation drawings.

  • The loop driver, by brand and model.
  • Loop wire or copper tape, with the total length for all phases, turns and cancellation loops.
  • For copper tape, adhesive tape in the same length.
  • Feeder cable: the number of runs and the length of each.
  • Lengths are modeled minimums, rounded up to 0.1 m or ft, with no allowance for site routing, slack or waste; the list asks you to confirm those and whole-roll quantities before approval.
Example: Civic Center Council ChamberExample
Materials to buy page from the example design report: loop driver, 14 AWG loop wire with its total length, and the 14/4 AWG quad feeder cable with the number of runs, each with its required quantity.
Open the example PDF: materials list, page 3 of the design report 3 pages · 315 KB · opens in a new tab
The materials list is page 3.

DXF for CAD

The loop geometry as a DXF file, so the layout can go onto the building drawings or into a specification package.

  • Each element on named layers for Phase A and Phase B, with polarity marks, element labels, the room walls and the room orientation, in meters.
  • A short note block: loop type, loop and room size, wall gaps, turns and units.
  • Series links and feeders are not drawn; the file says so.
  • Written in the long-established DXF R12 format, which CAD programs widely open.
Example: Civic Center Council ChamberExample
Plot of the example DXF: four overlapping elements in red for Phase A and blue for Phase B, with direction arrows, element labels and the room outline.
Download the example DXF: loop layout for CAD 16 KB

Site survey sheet

A printable set to take on the site visit, so the design starts from what is really there.

  • A survey protocol: choosing a test loop, and the steps for measuring metal loss at 100 Hz, 1 kHz and 5 kHz.
  • A record sheet: the venue, survey date, who surveyed and the meter used, then each test-loop reading with its frequency, test current, measured field, loop dimensions and location.
  • A page for sketching the floor plan: room and looped-section sizes, seating, the feeder route and length, rack space for the driver and how the loop will be installed.
  • A 50-point site evaluation checklist: venue use and coverage, construction and metal loss, flooring, ceiling and below-floor access, rack, power and audio, cable routing, noise and interference, and owner decisions.
Example: Civic Center Council ChamberExample
First page of the example site survey sheet: the test loop selection guide and the site testing procedure for measuring metal loss.
Open the example PDF: site survey sheet 4 pages · 217 KB · opens in a new tab
Printed for the site visit; only the designer’s name comes from the design.

Commissioning record

The certificate form the installer completes and signs after measuring the installed loop. It carries the project details and the plan from the design; the measurements are written in on site.

  • The design’s plan drawn into the sketch area, with the target listening height ticked as seated or standing.
  • Tables for measurement points A to K: the height and location of each point, the field strength (initial and final), and the frequency response at 100 Hz, 1 kHz and 5 kHz.
  • A background noise check, with problem zones marked on the sketch.
  • Boxes to tick for the field strength through the listening area, whether an overspill test is needed, the audio feed and a telecoil listening check.
  • Customer, venue, room, installer and equipment filled in from the design; serial numbers, the meter, the signature and the dates are left for the installer, who signs the declaration.
Example: Civic Center Council ChamberExample
First page of the example commissioning record: seated listening height of 3 feet 11 inches, the design’s plan drawn in the sketch area, a table of measurement points, a background noise check and a blank field strength table.
Open the example PDF: commissioning record 2 pages · 187 KB · opens in a new tab
Prefilled from the example design; the measurement fields are blank, as the app prints them.

In the app

See it, not read it

Screens from the same fictional project, captured from the app in US (imperial) units. Select a screen to see it larger.

  • Design setup window, Room and loop setup tab: a 66 by 44 foot loop in a 70 by 56 foot room with wall gaps of 10 feet at the front and 2 feet elsewhere, listening height 3 feet 11 inches, front of the room at the top, 14 AWG wire, a 14/4 AWG quad feeder of 85 feet, and the test-loop metal loss in use: 3 dB at 1 kHz and 6.5 dB at 5 kHz. (larger view)
    Design setup: loop and room size, wall gaps, listening height, front of the room, wire, feeder and metal loss.
  • Design setup, Names and locations tab filled in for the fictional project: designer, company, customer, venue, room, loop section, project number, revision, site address, issue status, issue date and checked by. (larger view)
    Names and locations print on every report and drawing title block.
  • Loop type list with Uniformity-optimized phased array selected: Perimeter loop, Figure-8 or sectioned loop, standard phased-array loop, Uniformity-optimized phased array, Low-spill-optimized phased array, and fixed seating presets with 3-row and 4-row elements. (larger view)
    Loop types, from a single perimeter loop to optimized phased arrays and fixed-seating presets.
  • Number of loops window for the uniformity-optimized phased array: array density 4, the Best balance goal selected, and the solved element length of 12 feet, overlap gap of 1 foot 4 inches, centerline ripple of 1.97 dB at listening height, and metal loss of 3.5 dB at 5 kHz. (larger view)
    Number of loops: the optimizer sizes the elements and their overlap for the goal you pick. Its metal-loss figure is the extra loss at 5 kHz over the loss at 1 kHz.
  • Metal loss calibration window, Test loop method, Readings step 5 of 6, with the test-loop loss in use in the design: without metal this test loop at 2.5 A should read 0 dB; the readings of minus 1.2, minus 3 and minus 6.5 dB at 100 Hz, 1 kHz and 5 kHz show a loss of 1.2, 3 and 6.5 dB under each box. (larger view)
    Metal loss from a test loop: type the meter readings and see the loss at each frequency.
  • Metal loss calibration window, Result step 6 of 6: at 100 Hz, 1 kHz and 5 kHz the meter readings of minus 1.2, minus 3 and minus 6.5 dB against 0 dB expected without metal, a metal loss of 1.2, 3 and 6.5 dB, and the metal loss used in the design: 3 dB at 1 kHz and 6.5 dB at 5 kHz. (larger view)
    The result: each reading against the value expected without metal, and the metal loss the design uses.
  • Driver list beside the sidebar for this design, which needs 9.5 V and 4.8 A per channel: two-channel drivers, each marked Suitable with bars for the required voltage and current against its rating. The selected driver is at the top, at 79 percent of its voltage and 97 percent of its current rating. (larger view)
    Driver list: each driver checked against the voltage and current this design needs.
  • Heat map tab: a top view of the field strength over the room, mostly green inside the loop, with red Phase A and blue Phase B elements and their positions, a color key in dB, and height maps across both axes below. (larger view)
    Heat map of the field over the whole loop, with each Phase A and Phase B element drawn in.
  • Cross section tab: the field level stays inside the green band from minus 3 to plus 3 dB over most of the looped area and falls away near the outer wires and in the spill zones beyond them, with labeled Phase A and Phase B wire positions, and a height map of the field from the floor up. (larger view)
    Cross section at listening height, with the wire positions and a height map below.
  • 3D field map: the field surface over the room in green, between transparent planes at plus and minus 3 dB, with a color key from minus 40 to plus 12 dB. (larger view)
    3D field map with the planes at plus and minus 3 dB.
  • Basic mode workspace: a heat map of the loop with element positions and a color key, and a cross section that stays inside the plus and minus 3 dB band away from the outer wires. (larger view)
    Basic mode: the same design with the essential controls.
  • Expanded Design details panel for the fictional project, its facts shown as tiles: project, loop, configuration, wire, driver and electrical sections, from customer, venue and room to loop size, wall boundary, metal loss, wire lengths, the selected driver with the voltage and current it needs, and the impedance and voltage of each channel. (larger view)
    Design details: every setting and result of the design on one panel.
  • Knowledge Library panel with topics for design setup, metal loss, cancellation loops, feeder cables, and wire and tape; the wire and tape topic is open. (larger view)
    The Knowledge Library explains each part of the design in plain words.
  • Admin driver database table: built-in drivers, each with an Active tick, its channel count, RMS and peak current, and RMS voltage. (larger view)
    Admin: the driver database, with the ratings the suitability check uses.
  • Admin table of wires, tapes and cables: round wires from 22 to 12 AWG and metric sizes from 0.34 to 1 square millimeter, each with a Show in lists checkbox, brand, part number, label, type, cross-section and DC resistance per meter. (larger view)
    Admin: the wire, tape and cable list, with the conductor sizes the calculations use.

Outputs describe the plan

Reports and drawings show the loop you designed and the field the model predicts for it. They do not test or approve an installation. Installed performance is confirmed by commissioning with a field-strength meter, and the commissioning record is where those measurements go.

Want to see the outputs for a room like yours? Request access, or write to ask for a walkthrough.

Request access

Hearing Loop Designer accounts are set up on request. Tell us your name, your company and the kind of projects you design, and we will be in touch.

Request access